Lumit® Immunoassay Cellular Systems—Neosubstrates
No-Wash, One-Plate Immunoassays to Measure Common CRBN Neosubstrates
- Fast detection of target analytes directly from cell lysates in ~2 hours
- No wash, transfer or immobilization steps
- Sensitive luminescence-based detection
- Protocol compatible with both 384-well and 96-well plates
- Contact us to suggest additional neosubstrate assays you would like to see developed
Lumit® Immunoassay Cellular Systems—Neosubstrates
| Catalog No. | Product Name | Size | Price | Qty | |||
|---|---|---|---|---|---|---|---|
| CS366904 | Early Access Lumit® GSPT1 Immunoassay* | View Specifications | 100 assays | Preis anfragen | |||
| CS366908 | Early Access Lumit® GSPT1 Immunoassay** | View Specifications | 1,000 assays | Preis anfragen | |||
| CS366912 | Early Access Lumit® IKZF1 Immunoassay* | View Specifications | 100 assays | Preis anfragen | |||
| CS366916 | Early Access Lumit® IKZF1 Immunoassay** | View Specifications | 1,000 assays | Preis anfragen | |||
| CS366928 | Early Access Lumit® IKZF2 Immunoassay* | View Specifications | 100 assays | Preis anfragen | |||
| CS366932 | Early Access Lumit® IKZF2 Immunoassay** | View Specifications | 1,000 assays | Preis anfragen | |||
| CS366920 | Early Access Lumit® IKZF3 Immunoassay* | View Specifications | 100 assays | Preis anfragen | |||
| CS366924 | Early Access Lumit® IKZF3 Immunoassay** | View Specifications | 1,000 assays | Preis anfragen | |||
| CS366936 | Early Access Lumit® SALL4 Immunoassay* | View Specifications | 100 assays | Preis anfragen | |||
| CS366940 | Early Access Lumit® SALL4 Immunoassay** | View Specifications | 1,000 assays | Preis anfragen |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
*These immunoassays are sufficient for 100 assays in 96-well plates or 200 assays in 384-well plates.
**These immunoassays are sufficient for 1,000 assays in 96-well plates or 2,000 assays in 384-well plates.
Fast Quantification of Common Neosubstrates for CRBN-Based Degraders
Lumit® Immunoassay Cellular Systems for Neosubstrates enable rapid measurement of 5 common CRBN neosubstrates (GSPT1, IKZF1, IKZF2, IKZF3, and SALL4) directly in cell lysates. No cell line engineering is required. Optimized antibody formulations simplify adaptation across cell lines of interest. Researchers can quickly assess both on-target degradation and off-target neosubstrate liabilities in the cellular contexts most relevant to their therapeutic application.
Why is neosubstrate selectivity critical in CRBN-based degrader development?
Targeted protein degradation (TPD) harnesses cellular machinery to eliminate disease-relevant proteins. CRBN-based degraders have achieved the greatest clinical success to date. A key challenge is characterizing neosubstrate degradation specificity, the proteins that become degradation targets through degrader-induced conformational changes to CRBN. For PROTACs, neosubstrates are off-target liabilities. For molecular glues, they are the intended targets. Either way, selectivity matters, since non-selective degradation of multiple neosubstrates poses safety risks. Protein expression and cellular context vary by cell type and disease state. This makes profiling in disease-relevant cell lines essential.
How the Assay Works
The Lumit® Immunoassay Cellular System does not require lysate transfer or wash steps, providing a simple, single-plate workflow. After treatment with degraders, cells are lysed, and an antibody mixture is added to detect the target analyte. The antibody mixture consists of two primary antibodies specific to the target and the matching SmBiT- and LgBiT-conjugated secondary antibodies. In the presence of the analyte, the antibodies come into close proximity, allowing SmBiT and LgBiT to form an active luciferase and generate a bright luminescence signal upon addition of detection reagent. Degradation of the target analyte will lead to a loss of signal.
Profile Neosubstrate Degradation Across Multiple Cell Lines
Quantify neosubstrate levels across diverse cell lines with Lumit® Immunoassays. Molecular glue-mediated degradation of GSPT1 (Panel A) and IKZF1 (Panel B) was assessed in various non-engineered cell lines after 3 hours or 24 hours of compound treatment. Degradation potencies and Dmax differed significantly across all cell lines.
Monitor Off-Target Degradation of Common Neosubstrates by CRBN Degraders
Evaluate specificity of CRBN degraders with Lumit® Immunoassays for CRBN Neosubstrates. The Lumit® Immunoassays for 5 common CRBN Neosubstrates are used to measure neosubstrate degradation by CRBN-based PROTACs targeting BTK/IKZF1/IKZF3 (left) or STAT3 (right). On-target degradation of IKZF1 and IKZF3, and partial off-target degradation of SALL4, were observed after treatment with the dual-modality BTK/IKZF1/IKZF3 PROTAC dd-03-171 for 3 hours. No off-target degradation was observed for the STAT3 PROTAC SD-36 following 24 hours of treatment. The following cell lines were used for profiling: HEK293 (GSPT1), Jurkat (IKZF1 and IKZF2), MM.1S (IKZF3), PA-1 (SALL4), Ramos (BTK) and K562 (STAT3).
Looking for validated Lumit® Immunoassays against additional targets?
Visit the Lumit® Immunoassay Cellular Systems product page.
Specifications
Catalog Number:
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-GSPT1 mAb (Rabbit) |
CS366901 | 1 × 30μl |
Anti-GSPT1 mAb (Mouse) |
CS366902 | 1 × 30μl |
Digitonin |
G944C | 1 × 50μl |
Lumit® Detection Substrate C |
VB103A | 1 × 200μl |
Lumit® Immunoassay Buffer C, 10X |
VB115A | 1 × 1.5ml |
Lumit® Lysis Buffer II, 10X |
VB310A | 1 × 500μl |
Lumit® Anti-Mouse Ab-LgBiT |
W102A | 1 × 30μl |
Lumit® Anti-Rabbit Ab-SmBiT |
W103A | 1 × 30μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 1 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-GSPT1 mAb (Rabbit) |
CS366905 | 1 × 300μl |
Anti-GSPT1 mAb (Mouse) |
CS366906 | 1 × 300μl |
Digitonin |
G944D | 1 × 500μl |
Lumit® Detection Substrate C |
VB103B | 2 × 1ml |
Lumit® Immunoassay Buffer C, 10X |
VB115B | 1 × 15ml |
Lumit® Lysis Buffer II, 10X |
VB310B | 1 × 5ml |
Lumit® Anti-Mouse Ab-LgBiT |
W102B | 1 × 300μl |
Lumit® Anti-Rabbit Ab-SmBiT |
W103B | 1 × 300μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 2 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-IKZF1 mAb (Rabbit) |
CS366909 | 1 × 30μl |
Anti-IKZF1 mAb (Mouse) |
CS366910 | 1 × 30μl |
Lumit® Anti-Rabbit Ab-LgBiT |
W104A | 1 × 30μl |
Lumit® Anti-Mouse Ab-SmBiT |
W105A | 1 × 30μl |
Digitonin |
G944C | 1 × 50μl |
Lumit® Detection Substrate C |
VB103A | 1 × 200μl |
Lumit® Immunoassay Buffer C, 10X |
VB115A | 1 × 1.5ml |
Lumit® Lysis Buffer II, 10X |
VB310A | 1 × 500μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 1 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-IKZF1 mAb (Rabbit) |
CS366913 | 1 × 300μl |
Anti-IKZF1 mAb (Mouse) |
CS366914 | 1 × 300μl |
Lumit® Anti-Rabbit Ab-LgBiT |
W104B | 1 × 300μl |
Lumit® Anti-Mouse Ab-SmBiT |
W105B | 1 × 300μl |
Digitonin |
G944D | 1 × 500μl |
Lumit® Detection Substrate C |
VB103B | 2 × 1ml |
Lumit® Immunoassay Buffer C, 10X |
VB115B | 1 × 15ml |
Lumit® Lysis Buffer II, 10X |
VB310B | 1 × 5ml |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 2 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-IKZF2 mAb (Rabbit) |
CS366925 | 1 × 30μl |
Anti-IKZF2 mAb (Mouse) |
CS366926 | 1 × 30μl |
Digitonin |
G944C | 1 × 50μl |
Lumit® Detection Substrate C |
VB103A | 1 × 200μl |
Lumit® Immunoassay Buffer C, 10X |
VB115A | 1 × 1.5ml |
Lumit® Lysis Buffer II, 10X |
VB310A | 1 × 500μl |
Lumit® Anti-Mouse Ab-LgBiT |
W102A | 1 × 30μl |
Lumit® Anti-Rabbit Ab-SmBiT |
W103A | 1 × 30μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 1 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-IKZF2 mAb (Rabbit) |
CS366929 | 1 × 300μl |
Anti-IKZF2 mAb (Mouse) |
CS366930 | 1 × 300μl |
Digitonin |
G944D | 1 × 500μl |
Lumit® Detection Substrate C |
VB103B | 2 × 1ml |
Lumit® Immunoassay Buffer C, 10X |
VB115B | 1 × 15ml |
Lumit® Lysis Buffer II, 10X |
VB310B | 1 × 5ml |
Lumit® Anti-Mouse Ab-LgBiT |
W102B | 1 × 300μl |
Lumit® Anti-Rabbit Ab-SmBiT |
W103B | 1 × 300μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 2 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-IKZF3 mAb (Rabbit) |
CS366917 | 1 × 30μl |
Anti-IKZF3 mAb (Mouse) |
CS366918 | 1 × 30μl |
Digitonin |
G944C | 1 × 50μl |
Lumit® Detection Substrate C |
VB103A | 1 × 200μl |
Lumit® Immunoassay Buffer C, 10X |
VB115A | 1 × 1.5ml |
Lumit® Lysis Buffer II, 10X |
VB310A | 1 × 500μl |
Lumit® Anti-Mouse Ab-LgBiT |
W102A | 1 × 30μl |
Lumit® Anti-Rabbit Ab-SmBiT |
W103A | 1 × 30μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 1 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-IKZF3 mAb (Rabbit) |
CS366921 | 1 × 300μl |
Anti-IKZF3 mAb (Mouse) |
CS366922 | 1 × 300μl |
Digitonin |
G944D | 1 × 500μl |
Lumit® Detection Substrate C |
VB103B | 2 × 1ml |
Lumit® Immunoassay Buffer C, 10X |
VB115B | 1 × 15ml |
Lumit® Lysis Buffer II, 10X |
VB310B | 1 × 5ml |
Lumit® Anti-Mouse Ab-LgBiT |
W102B | 1 × 300μl |
Lumit® Anti-Rabbit Ab-SmBiT |
W103B | 1 × 300μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 2 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-SALL4 mAb (Rabbit) |
CS366933 | 1 × 30μl |
Anti-SALL4 mAb (Mouse) |
CS366934 | 1 × 30μl |
Digitonin |
G944C | 1 × 50μl |
Lumit® Detection Substrate C |
VB103A | 1 × 200μl |
Lumit® Immunoassay Buffer C, 10X |
VB115A | 1 × 1.5ml |
Lumit® Lysis Buffer II, 10X |
VB310A | 1 × 500μl |
Lumit® Anti-Mouse Ab-LgBiT |
W102A | 1 × 30μl |
Lumit® Anti-Rabbit Ab-SmBiT |
W103A | 1 × 30μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 1 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Lieferumfang
| Produkt | Katalognummer | Größe |
|---|---|---|
Anti-SALL4 mAb (Rabbit) |
CS366937 | 1 × 300μl |
Anti-SALL4 mAb (Mouse) |
CS366938 | 1 × 300μl |
Digitonin |
G944D | 1 × 500μl |
Lumit® Detection Substrate C |
VB103B | 2 × 1ml |
Lumit® Immunoassay Buffer C, 10X |
VB115B | 1 × 15ml |
Lumit® Lysis Buffer II, 10X |
VB310B | 1 × 5ml |
Lumit® Anti-Mouse Ab-LgBiT |
W102B | 1 × 300μl |
Lumit® Anti-Rabbit Ab-SmBiT |
W103B | 1 × 300μl |
Antibody Dilution Buffer |
W108A | 1 × 1ml |
GF-AFC Substrate |
G608A-C | 2 × 10μl |
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.
Resources
Zusätzliches Informationsmaterial
Related Products
Ähnliche Produkte
Lumit® Immunoassay Cellular Systems
A no-wash bioluminescent immunoassay to measure levels of target analytes in cell lysates.
W1201, W1202, W1203, W1331, W1332, W1333, W1220
Lumit® Immunoassay Cellular Systems—Complete Assays
A no-wash one-plate immunoassay to detect specific cellular analytes.
CS3397A03, CS3397A04, CS3397A07, CS3397A08, CS3397A11, CS3397A12, CS3397A15, CS3397A16, CS3397A19, CS3397A20, CS3397A26, CS3397A30, CS3397A34, CS3397A38, CS3397A42, CS3397A46, CS3397A50, CS3397A54, CS3397A58, CS3397A62, CS366104, CS366108, CS366112, CS366116, CS366120, CS366124, CS366128, CS366132, CS366136, CS366140, CS366144, CS366148, CS366152, CS366156, CS366160, CS366164, CS366168, CS366172, CS366176, CS366180
Wird oft zusammen gekauft
Lumit® Immunoassay Lysis and Detection Kits and Secondary Antibodies
Components of the Lumit® Immunoassay Cellular Systems that bundle the Lysis and Detection Kit reagents with specific Secondary Antibody pairs.
W1021, W1022, W1031, W1032, W1041, W1042, W1051, W1052, W1061, W1062, W1231, W1232, W1233
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000